FAULT FINDING
The fault nding guide covers common symptoms, causes and solutions that
are likely to be encountered by the average user.
If an issue with the GEO3.5 cannot be solved using the fault nding guide,
contact your nearest Eclipse Service Centre for assistance.
SYMPTOM POSSIBLE CAUSE SOLUTION
Although a fresh battery has been tted, the GEO3.5
will not switch on
The battery has been tted incorrectly
Fit the battery correctly with the positive terminal
nearest to the side of the frame
The battery has drained on the shelf Replace with another fresh battery
The battery terminals are not making proper contact
with the battery
Remove the battery, gently bend the terminals
towards where the battery will sit and then replace
the battery
The battery does not seem to last very long The battery type is of a low quality
Use an alkaline or metal hydride battery
Do not use a low quality or rechargeable battery
The GEO3.5 does not re
The POPS is not engaged Engage the POPS fully
Solenoid Flow Restrictor (SFR) set too low Increase the ow through the SFR
The SFR assembly is blocked Strip and clean the SFR assembly
Battery quality or level of charge is very low Install new high quality battery
Battery is at Install new high quality battery
Training mode is enabled Disable training mode
Trigger and trigger detection method are set up
incorrectly
Set up the trigger correctly (refer to “Setting the
trigger” section)
Trigger detection system is blocked
Remove any wires or debris from the trigger
detection system
Solenoid assembly is not plugged into GEO3.5 PCB
correctly
Plug solenoid assembly plug into the solenoid port
on the GEO3.5 PCB
The break beam sensor system is enabled but there
are no paintballs in the breech
Fill the loader with paint/ turn on loader