Manual
Thebreakbeamsensorsystemdoesnot
appeartobereadingcorrectly.
Thebreakbeamsensorsystemisnotreading
atall.
Twoormoreballsarebeingfedintothe
breech.
Thebreakbeamsensorsystemturnsitselfoff
afterfiring.
WhentheGEO3.1powersup,therighthand
sideofthescreenisnotdisplayedandthe
markerwillnotfire.
Thebreakbeamsensorsystemisdirty.
Thebreakbeamsensorsarethewrongway
around.
Thereisabrokenwireorcontact,orashort
circuitoneitherofthebreakbeamsensor
cables.
Eitherbreakbeamsensorisbacktofront.
Therubberdetentsarebroken/missing.
Loaderfeedforceissettoohigh.
Theeyeisdirty.
Theeyeisfaulty.
Theeyeisoutofplace.
Thetriggerispermanentlydepressed.
Cleanthebreakbeamsensorsystem.
Checkthattheredreceiverisontheright-
handsideofthebreech.
Checktheplugonthecables.
Checkforcutsorpinchesinthesensor
cables.
Checkthatthesensorsfaceeachotherwhen
installed.
Changetherubberfingerdetents.
Reducethefeedforceontheloader.
Cleantheeyes.
Replacetheeyes.
Re-installtheeyesthencheckthealignment.
Adjustthetriggeruntiltheselectedtrigger
detectionmethodisactivatedwhenthe
triggerisreleased.
TheFaultFindingguidecoverscommonsymptoms,causesandsolutionsthatarelikelytobeencounteredbytheaverageuser.Ifanissue
withtheGEO3.1cannotbesolvedusingtheFaultFindingguide,contactyournearestEclipseServiceCentreforassistance.
SYMPTOM POSSIBLE CAUSE SOLUTION
FAULT FiNDiNG 65