Manual

BeforeusingtheGEO3.1itisimportanttomakesuretheSL4
inlineregulator,solenoidflowrestrictor(SFR)andallelectronically
controlledparametersaresetcorrectly.Allofthesecanhavea
negativeeffectontheperformanceofthemarkerifsetincorrectly.
ThestepsbelowwillrestoretheGEO3.1settingstothefactory
settings.ThesesettingswillgivetheGEO3.1amorebalanced
performance,idealfortheaverageuser.
INLINEREGULATOROUTPUTPRESSURE
Checktheinlineregulatoradjusterscrewissetto4
1/2
turnsclockwise
fromitsmaximumoutposition
(SEEFIGURE1A)
.Thiswillensurethe
SL4inlineregulatorissettoanoutputpressurethatwillnotdamage
theGEO3.1whensuppliedwithcompressedair/nitrogen(seepage
18formoreinformationonSL4inlineregulatoradjustment).
SOLENOIDFLOWRESTRICTORSETTINGS
Checkthatthesolenoidflowrestrictor
(SEEFIGURE1B)
issetas
pictured.Seepage19formoreinformationonthesolenoidflow
restrictor.
ELECTRONICALLYCONTROLLEDPARAMETERS
LoadtheFACTORYpreset
(SEEFIGURE1C)
storedontheGEO3.1
circuitboard.Thispresetwillrestorealltheelectronicparametersto
theirdefaultsettings.Seepage29onloadingtheFACTORYpreset.
FACTORY SET-UP GUiDE
FIG1A
FIG1B
FIG1C
DE-GAS YOUR MARKER, DISCHARGING ANY STORED GAS IN
A SAFE DIRECTION, AND REMOVE THE BARREL, LOADER, AIR
SYSTEM AND ANY PA INTBALLS TO MAKE THE MARKER
EASIER AND SAFER TO WORK ON.
WARNING
6 USiNG THE GEO3.1