Manual

HavingremovedtheframecompletelyfromtheGEO3.1body(see
page51).UnscrewthetwoM2.5x5retainingscrewswhichholdthe
bearingcarrierintheframe
(SEEFIGURE24A)
.
Gentlyliftthebearingcarrierandtriggerassemblyfreefromthe
frametakingcarenottodamagethemicro-switchortheOPTO
sensors
(SEEFIGURE24B)
.
Removethetriggerspringfromthebearingcarrier,removingany
paintormoisture
(SEEFIGURE24C)
.
Usinga1/16”hexkey,loosenthetriggerpinretainingsetscrewfrom
thebackofthetrigger
(SEEFIGURE24D)
.
Useasmallhexkeytopushthetriggerpinoutofthebearingcarrier
fromoneside
(SEEFIGURE24E)
,thenremovethebearingcarrierfrom
thetrigger
(SEEFIGURE24F)
.
Cleanthetriggerandbearingcarrierthoroughlyandalsocleanthe
spacewithintheframethatthetriggersitsin.
THE TRiGGER ASSEMBLY
DE-GAS YOUR MARKER, DISCHARGING ANY STORED GAS IN
A SAFE DIRECTION, AND REMOVE THE BARREL, LOADER, AIR
SYSTEM AND ANY PA INTBALLS TO MAKE THE MARKER
EASIER AND SAFER TO WORK ON.
WARNING
FIG24A
FIG24C
FIG24D
FIG24B
FIG24E
FIG24F
54 MAiNTENANCE