Removaloftheframeisrequiredforaccesstothesolenoid
assembly,triggerbearingcarrierassemblyandBreakBeamSensor
Systemwiresifmaintenanceoneitherisrequired.
Disconnectanyhosingandunscrewtheinlineregulatorfromthe
FrontRegulatorMount(FRM)asdetailedinthe‘Cleaningtheinline
regulator’sectionofthisMaintenanceGuide.
Usinga5/64”hexkey,removethefourscrewsthatattachthe
GEO3.1rubbergripstotheGEO3.1frame
(SEEFIGURE21A)
.
UnplugthesolenoidandtheBreakBeamSensorSystemwiring
harnessesfromtheirrespectiveportsontheGEO3.1circuitboard
(SEEFIGURE21B)
.
Usinga1/8”hexkey,unscrewbutDONOTREMOVEthefrontframe
screwlocatedundertheforegripcrown
(SEEFIGURE21C)
.
Usingtheshortarmofa1/8”hexkey,loosentherearframescrew
2-3fullturns
(SEEFIGURE21D)
.
Slidetheframebackwardsapproximatelyhalfaninchsothat
therearframescrewdisengagesfromtheframeandremovethe
framefromtheGEO3.1bodytakingcarenottodamageanywires
(SEEFIGURE21E)
.
YouhavenowremovedyourGEO3.1framefromtheGEO3.1body.
REMOViNG THE FRAME
IF YOU ARE UNSURE ABOUT PERFORMING A MAINTENANCE
PROCEDURE PLEASE CONTACT YOUR NEAREST SERVICE
CENTRE.
WARNING
DE-GAS YOUR MARKER, DISCHARGING ANY STORED GAS IN
A SAFE DIRECTION, AND REMOVE THE BARREL, LOADER, AIR
SYSTEM AND ANY PA INTBALLS TO MAKE THE MARKER
EASIER AND SAFER TO WORK ON.
WARNING
FIG21C
FIG21E
FIG21A
FIG21D
FIG21B
MAiNTENANCE 51