Removetheinlineregulatorascoveredonpage44.TurntheGEO3.1
upsidedowntorevealthebodyfilterinsidethebody
(SEEFIGURE18A)
.
Usinga5/64”hexkeyunscrewandremovetheretainingscrew
(SEE
FIGURE18B)
.
Thenremovethebodyfilter
(SEEFIGURE18C)
.
Inspectandcleanthebodyfilter.Ifthefilterisverydirtyreplacewith
anewfilter.
Insertthefilter
1
intotheFRMontheGEO3.1body,ensuringthehole
inthefilterlinesupwiththethreadsinthebody
(SEEFIGURE18D)
.
Usinga5/64”hexkey,replacetheretainingscrew.DONOTover
tightentheretainingscrewasthismayresultinthefilterbeing
crushedbetweenthescrewandGEO3.1body
(SEEFIGURE18E)
.
Re-attachtheinlineregulatortotheGEO3.1.
IfaftercleaningtheGEO3.1isstillexperiencingslowpurgeandlow
velocityissuesthefiltermayneedreplacing.
1
If the filter has only been cleaned and not replaced with a new one, ensure the filter is inserted
back into the body facing the same way it was removed. This will prevent any dirt embedded in
the filter being blow into the bolt system of the marker when supplied with compressed air.
CLEANiNG THE BODY FiLTER
IF YOU ARE UNSURE ABOUT PERFORMING A MAINTENANCE
PROCEDURE PLEASE CONTACT YOUR NEAREST SERVICE
CENTRE.
WARNING
DE-GAS YOUR MARKER, DISCHARGING ANY STORED GAS IN
A SAFE DIRECTION, AND REMOVE THE BARREL, LOADER, AIR
SYSTEM AND ANY PA INTBALLS TO MAKE THE MARKER
EASIER AND SAFER TO WORK ON.
WARNING
FIG18A
FIG18B
FIG18D
FIG18C
FIG18E
MAiNTENANCE 47