Themagnetreturnstrengthscrewisusedtoadjusttheamountof
forcewithwhichthetriggerisreturnedtoitsrestpositionbythe
magnet.Turnthescrewclockwisetoincreasetheamountofforce.
Donotturnthescrewtoofaroritwillnegatethepositionofthefront
stopscrew.Turnthescrewcounter-clockwisetoreducetheamount
offorce.Donotturnthescrewtoofarortheremaynotbeenough
forcetoreturnthetrigger
(SEEFIGURE7D)
.
Themicro-switchactivationscrewisusedtoadjustthepointinthe
triggerpullatwhichthemicro-switchisactivated(onlyiftheTrigger
parameteronpage37issetto‘SWITCH’).Turnthescrewclockwise
todecreasetheamountoftriggertraveltotheactivationpoint.Turn
thescrewcounter-clockwisetoincreasetheamountoftriggertravel
totheactivationpoint
(SEEFIGURE7E)
.Donotsetthemicro-switch
activationscrewtoofaroutwhenusingtheOPTOsensors,asthe
screwcanstopagainstthemicro-switchbeforethetriggerprong
enterstheOPTOsensors.
Thespringreturnstrengthscrewisusedtoadjustthespring
strengththatreturnsthetriggertoitsrestingposition.Turnthescrew
clockwisetoincreasetheamountofspringreturnstrengthinthe
triggerpull.Turnthisscrewcounter-clockwisetoreducetheamount
ofspringreturnstrengthinthetriggerpull.Donotturnthescrewtoo
farcounter-clockwiseortherewillnotbeenoughforcetoreturnthe
triggerconsistently
(SEEFIGURE7F)
.
Whensettingthetriggeritisimportanttoensurethattheelectronic
triggerdetectionisworkingcorrectly.Whenthetriggerisfully
depressedtheTriggerDetectionIndicator(TDI)shouldpointupwards
.WhenthetriggerisfullyreleasedtheTDIshouldpoint
downwards
.
Formoreinformation,seeunderstandingtheTriggerDetection
Indicator(TDI)onpage24andtheFiltermenuonpages34-36.