Manual
THE GEO2 ON/OFF PURGE
SYSTEM OOPS
Having disconnected the macroline hose from the tting
on the OOPS body, unscrew the OOPS knob from the
OOPS body SEE FIGURE 15.1. Clean o any dirt, debris or
moisture from the OOPS knob and the threaded section of
the OOPS body.
Use an appropriately sized hex key to push the OOPS pin
out of the OOPS body SEE FIGURE 15.2 and then remove
the OOPS insert using a pair of needle nosed pliers SEE
FIGURE 15.3.
Clean and check the condition of the two 008 NBR70
o-rings on the outside of the OOPS insert, replacing as
necessary SEE FIGURE 15.4.
WARNING: DEGAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE THE
BARREL, LOADER, AIR SYSTEM AND ANY PAINTBALLS
TO MAKE THE MARKER EASIER AND SAFER TO WORK
ON.
FIG 15.2
FIG 15.3
FIG 15.1
FIG 15.4
CONTENTS
ORIENTATION
QUICK SET-UP
USING YOUR GEO2
ADVANCED SET-UP
MENU TREE
MAINTENANCE
FAULT FINDING
SERVICE CENTRES
PARTS LIST
SPARES & ACCESSORIES
E-PORTAL
INDEX
63.
MAINTENANCE
MAINTENANCE
QUICK GUIDE