Manual

DEBOUNCE
THE DEBOUNCE PARAMETER
The DEBOUNCE parameter is used to combat
any trigger bounce that might occur in the
Geo2 and can be set between level 1 and
level 9 in one level increments.
> LEVEL 9:
Level 9 providing the most
ltering (least ‘bouncy’).
> LEVEL1:
Level 1 providing the least
ltering (most ‘bouncy’).
> CANCEL:
Cancel editing and leave the parameter
unchanged.
EMPTY
THE BREECH EMPTY TIME
PARAMETER
In order for the BBSS to function correctly
it must rst detect that the bolt is fully
retracted and the breech is empty, and then
detect that a paintball is loaded into the
breech before the Geo2 is allowed to re.
The parameter can be set between 1.0 and
20.0ms in 0.5ms increments.
FULL
THE BREECH FULL TIME PARAMETER
Tumbling paintballs can take time to
settle in the breech before they can be
successfully red. This parameter is used
to set the amount of time that a paintball
has to be in the breech before the Geo2 is
allowed to re. This parameter can be set
between 1.0 and 20 milliseconds in 0.5ms
increments.
PULL TM
THE TRIGGER PULL TIME PARAMETER
The PULL TM parameter is used to set the
minimum amount of time that the trigger
must be pulled before it is recognised as a
valid trigger pull. This parameter can be set
between 3.0 and 20.0 milliseconds in 0.5
increments.
RELEASE TM
THE TRIGGER RELEASE
TIME PARAMETER
The RELEASE TM parameter is used to set the
minimum amount of time that the trigger
must be released before it is recognised as a
valid trigger release. This parameter can be
set between 3.0 and 25.0 milliseconds in 0.1
millisecond increments.
PULL PT
THE TRIGGER PULL POINT
PARAMETER
The PULL PT parameter is only available if
OPTO has been selected in the HARDWARE
menu. PULL PT denes the point at which
the trigger is considered pulled and is
adjustable between 51% and 99% in 1%
increments.
RELEASE PT
THE TRIGGER RELEASE POINT
PARAMETER
The RELEASE PT parameter is only available
if OPTO has been selected in the HARDWARE
menu. RELEASE PT denes the point at which
the trigger is considered released and is
adjustable between 1% and 49% in 1%
increments.