Manual
HOW TO REMOVE THE
FRAME
Disconnect any hosing and unscrew the Inline Regulator
from the Front Regulator Mount (FRM) as detailed in
the ‘CLEANING THE INLINE REGULATOR’ section of this
Maintenance Guide.
Using a 5/64” hex key, remove the six screws that attach the
Geo2 Rubber Grips to the Geo2 Grip Frame SEE FIGURE
12.1.
Unplug the Solenoid and the Break Beam Sensor System
wiring harnesses from their respective ports on the Geo2
Circuit Board SEE FIGURE 12.2.
Using a 1/8” hex key, undo and remove the Front Frame
Screw SEE FIGURE 12.3. Using the short arm of a 1/8” hex
key, loosen the Rear Frame Screw a full turn SEE FIGURE
12.4
. Slide the Frame backwards approximately half an
inch so that the Rear Frame Screw disengages from the
Frame and remove the Frame from the Geo2 Body taking
care not to damage any wires SEE FIGURE 12.5.
You have now removed your Geo2 Grip Frame from the
Geo2 Body and have access to the Solenoid Assembly
and Break Beam Sensor System wires if maintenance on
either is required. Also access to the Trigger Spring Return
Strength adjuster screw.
WARNING: IF YOU ARE AT ALL UNSURE AT PERFORMING
THE MAINTENANCE PROCEDURE PLEASE CONTACT YOUR
NEAREST ECLIPSE SERVICE CENTRE. SEE PAGE 69
WARNING: DEGAS YOUR MARKER, DISCHARGING
ANY STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER AND AIR SYSTEM TO MAKE THE
MARKER EASIER TO WORK ON.
FIG 12.4
FIG 12.2FIG 12.1
FIG 12.5
FIG 12.3
CONTENTS
ORIENTAT ION
QUICK SET-UP
USING YOUR GEO2
ADVANCED SET-UP
MENU TREE
MAINTENANCE
FAULT FINDING
SERVICE CENTRES
PARTS LIST
SPARES & ACCESSORIES
E-PORTAL
INDEX
55.
mAINTENANCE
MAINTENANCE
QUICK GUIDE