Manual

BASIC TRIGGER
FILTER SETUP
95% of trigger bounce problems can be eliminated by
utilizing one of the nine xed
DEBOUNCE
choices
(LEVEL 1-9). In attempting to eliminate trigger bounce it
is advisable to try the nine xed
DEBOUNCE
choices before
attempting any advanced set up of the trigger lters.
ADVANCED TRIGGER
FILTER SETUP
In order to optimize the trigger lters it is necessary to
have the PULL PT parameter set as high as possible and the
RELEASE PT parameter set as low as possible:
1. Select the PULL PT parameter. Observe that the graphical
bar rises and falls as the trigger is pulled and released. The
actual value of the graphical bar is displayed in the top
right of the display.
2. Set the Rear Stop Trigger Screw as required, ensuring
that the bar is as close to 100% as possible when the
trigger is fully depressed against the set screw. It is
advisable to allow for some extra travel in the trigger pull
once the bar has reached its maximum value.
3. Adjust the PULL PT parameter so that when the trigger is
fully depressed the bar settles above the indicator on the
left hand side of the screen (see page 39).
4. Select the RELEASE PT parameter. Observe that the
graphical bar rises and falls as the trigger is pulled and
released. The actual value of the graphical bar is displayed
in top right of the display.
5. Set the Front Stop Trigger Screw as required, ensuring
that the bar is as close to 0% as possible when the trigger
is fully released against the set screw. It is advisable to
allow for some extra travel in the trigger release once the
bar has reached its minimum value.
6. Adjust the
RELEASE PT parameter so that when the
trigger is fully released the bar settles beneath the
indicator on the left hand side of the screen (see page 39).
7. Set the Magnet Return Strength Screw and the Spring
Return Strength Screw as required, making both the spring
tension and the return force as strong as possible without
compromising the “feel” of the trigger.
HARDWARE
THE HARDWARE MENU
The HARDWARE menu comprises parameters that control
low level functionality of the Geo2 electronic hardware.
40.
ADVANCED SET-UP