Manual

ATTACHING THE FRAME
Firstly ensure the BBSS wires are secured in the
wire channel on the underside the Etha body
(SEE
FIGURE 20A)
.
Carefully thread the solenoid and BBSS wires through
the access holes in the top of the frame
(SEE
FIGURE 20B)
. Making sure that the BBSS and
solenoid wires are not trapped between the frame,
solenoid valve and body, re-attach the frame to the Etha
body by tightening the two frame screws using a 1/8”
hex key
(SEE FIGURES 20C & 20D).
If the frame is difficult to attach, ensure that the BBSS
wires are still in the wire channel under the Etha body
and do not interfere with the trigger spring.
Re-connect the solenoid and BBSS to their respective
sockets on the Etha circuit board
(SEE FIGURE
20E)
.
Adjust both the solenoid and BBSS wires so that they
sit neatly within the frame, making sure the wires do
not interfere with the micro-switch
(SEE FIGURE
20F)
.
Re-attach the grip panels to the frame by using a 5/64”
hex key to tighten the two grip screws.
IF YOU ARE AT ALL UNSURE OF PERFORMING A
MAINTENANCE PROCEDURE PLEASE CONTACT
YOUR NEAREST SERVICE CENTRE.
DE-GAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER, AIR SYSTEM AND ANY
PAINTBALLS TO MAKE THE MARKER EASIER AND
SAFER TO WORK ON.
FIG 20A
FIG 20C
FIG 20B
FIG 20D
FIG 20E
FIG 20F