Manual
REMOVING THE FRAME
Disconnect the macroline hose and unscrew the inline
regulator from the Etha body as detailed in the SL3
inline regulator section of this maintenance guide
(pages 36-37).
Using a 5/64” hex key remove the screws that attach
the grip panels to the frame, then remove the grip
panels
(SEE FIGURE 19A). Unplug the solenoid and
BBSS wires from their sockets on the Etha circuit board
(SEE FIGURE 19B).
Using a 1/8” hex key undo the two frame screws
(SEE FIGURES 19C & 19D) and remove the frame
from the Etha body, taking care not to damage any
wires or the solenoid valve
(SEE FIGURE 19E).
You have now removed the frame.
IF YOU ARE AT ALL UNSURE OF PERFORMING A
MAINTENANCE PROCEDURE PLEASE CONTACT
YOUR NEAREST SERVICE CENTRE.
DE-GAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER, AIR SYSTEM AND ANY
PAINTBALLS TO MAKE THE MARKER EASIER AND
SAFER TO WORK ON.
F IG 19A
F IG 19B
F IG 19C
F IG 19D
F IG 19E
MAIntEnAnCE
44
Etha-Manual-v2.indd 44 13/02/2017 13:11