REPLACING THE 9V BATTERY
Ensure that the Etha is switched off. Place the marker
on a flat surface in front of you with the feed tube
furthest away from you and the barrel pointing to the
right.
Using a 5/64” (2mm) hex key, remove the
countersunk screw towards the bottom of the frame
that holds the grip panel onto the frame. Lift the grip
panel up to expose the electronics within the frame.
Remove the existing 9 volt battery by sliding your
finger into the recess provided below the battery
and gently lever the battery out of the frame
(SEE
FIGURE 3A)
.
On top of the battery you will see the battery connector
that is used to connect the battery to the circuit board.
Gently separate the battery connector from the battery,
so that the existing battery can be disposed of
responsibly, then taking a new 9 volt Alkaline battery
(type PP3, 6LR61, MN1064)
1
connect it to the battery
connector
(SEE FIGURE 3B).
The battery will only connect to the battery connector
one way. If you are unsure of how to install a new
battery please contact your nearest Eclipse Service
Centre.
Ensure that all of the wires are within the recess
of the frame and not trapped in the micro-switch or
trigger spring, then replace the grip panel and tighten
the countersunk screw using the 5/64
(2mm) hex key.
DO NOT OVER-TIGHTEN THE GRIP SCREW.
1
Do not use rechargeable batteries or low quality batteries.
2
Some brands 9V batteries may be too large for the Etha battery
compartment in the grip frame. When installing a 9V battery, if
it does not fit correctly, do not force the battery into place as the
frame or battery connector may be damaged as a result.
FIG 3A
+
-