Manual

FACTORY SET-UP GUIDE
Before using the Etha it is important to make sure
that the inline regulator and all electronically controlled
parameters are set correctly, as some of these may
have a negative (and potentially damaging) effect on
the marker, in terms of performance and reliability, if
incorrectly set.
The steps below will restore the Etha to the state that
it left the factory.
-Reset the control parameters to the factory settings
(see page 33).
-Check the inline regulator adjuster screw is set to 2
1/2
turns clockwise from its maximum output (counter-
clockwise) position
(SEE FIGURE 2A). This will
ensure the inline regulator is set to an output pressure
that will not damage the Etha when supplied with
compressed air/nitrogen (see page 26 for more
information on the inline regulator).
DE-GAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER, AIR SYSTEM AND ANY
PAINTBALLS TO MAKE THE MARKER EASIER AND
SAFER TO WORK ON.
FIG 2A
QuI
ck Set-up
10