FAULT FINDING
FAULT FINDING TABLES
SYMPTOM POSSIBLE CAUSE SOLUTION
Low rate of re/rate of re not
reaching the ROF cap.
The force setting of the loader is too low. Adjust the loader force feed setting.
The breech sensor is defaulting and
reducing the ROF.
Check the position and condition of the breech sensors.
Clean or replace the breech sensor light pipes as required.
The marker is breaking paintballs
in the barrel or breech.
The ball detents are damaged or missing. Replace the ball detents.
The force setting of the loader is too high. Reduce the loader force feed setting.
The paint is poor quality. Try a higher grade of paint.
The breech sensor is switched off. Switch on the breech sensor.
The bolt and/or breech sensor is dirty Clean the bolt and breech sensor/light pipes.
The velocity is set too high. Check and adjust the velocity of the ETHA2.
The ETHA2 does not re.
The ETHA2 is not powered on. Power up the ETHA2 using the On/Of button.
The POPS is not fully engaged. Push in the POPS switch until it engages.
The battery quality or charge level is very low. Install new high quality alkaline or lithium battery.
The battery is at. Replace the battery.
The DWELL parameter is set too low. Increase the DWELL parameter.
The trigger is set-up incorrectly. Adjust trigger correctly to fully open and close the microswitch.
The solenoid is not plugged into the ETHA2 PCB. Plug solenoid wire into port on the ETHA2 PCB.
The breech sensor is enabled but there is
no paint in the breech.
Fill loader with paint.
Ensure loader is feeding paintballs into the breech.
The PCB is damaged. Replace PCB.
The solenoid pilot valve is damaged. Replace solenoid pilot valve.