Manual
17
ETHA2
ELECTRONICS
PRESETS
The Preset parameter is used to quickly set up the ETHA2 to operate within the rules of the most common paintball leagues.
Simply set the Preset parameter to the required value as shown in the table below.
VALUE MODE DESCRIPTION
1 SEMI ∞ Uncapped Semi-Automatic: one shot per trigger pull with no rate of re cap.
2 SEMI 15.0 Capped Semi-Automatic: one shot per trigger pull with a 15.0 bps cap.
3 WPBO WPBO / NXL / Millennium Series compliant ramping* with a 10.2 bps cap.
4 PSP PSP compliant ramping with a 10.2 bps cap.
*NOTE: At the time of writing, the WPBO preset covers both the NXL and Millennium Series leagues.
The rate of re caps used by the presets are safe values to allow for variations in rate of re measuring equipment.
To change the rate of re, rst set the preset parameter and then set the two maximum ROF parameters (GREEN and BLUE).