FAULT FINDING
SYMPTOM POSSIBLE CAUSE SOLUTION
BS turns itself off after ring and the display shows the BS
fault icon in the top right.
The sensor is dirty. Clean the BS.
The sensor is faulty. Replace the BS.
The sensor is out of place. Re-Install BS. Check alignment.
Two or more balls are being fed into the breech.
Worn/damaged Detents. Change the rubber Detent.
The feed force too high from loader. Adjust loader settings/use lower force loader.
ETEK5 is inconsistent.
The inline regulator is supercharging. Strip and clean inline regulator, replacing SL4 regulator seal.
The dwell is too low. Increase the dwell setting.
Poor quality paintballs. Use better quality paintballs.
Poor paintball size to barrel bore match. Use a closer paintball to barrel bore size.
Inconsistent air supply from air system. Use a good quality air system.
ETEK5 is inefcient.
The dwell is excessively high Reduce the dwell.
LPR is set too high. Reduce LPR output pressure.
Poor paintball size to barrel bore match Use a closer paintball to barrel bore size.
Leaking rammer assembly (Leak gets louder when bolt is
removed).
The front rammer shaft o-ring deteriorated. Replace the front rammer shaft o-ring.
When the ETEK5 powers up the LED ashes white or red. The trigger is permanently depressed.
Turn the front stop set screw in the top of the trigger
counter-clockwise until the microswitch is released. If there
is insufcient trigger adjustment then turn the return force set
screw counter-clockwise also.
The ETEK5 leaks out of the LPR body vent hole (small hole
behind the regulator sleeve on the left of the ETEK5 body).
The LPR piston o-ring or either of the two LPR body o-rings
are damaged or dirty.