Manual
ETEK5 MANUAL 59
FAULT FINDING
SYMPTOM POSSIBLE CAUSE SOLUTION
The ETEK5 res but the bolt doesn’t move. The bolt pin is not located in rammer correctly.
Lift bolt pin and line up with position of rammer correctly.
(See Maintenance section).
Low rate of re / rate of re not reaching the ROF cap. The force setting of the loader is too low. Adjust the loader force feed setting.
The marker is chopping or trapping paint.
The paint is poor quality. Try a higher grade of paint.
The Breech Sensor is switched off. Switch on the Breech Sensor.
The bolt and/or BS is dirty causing incorrect detection of paintballs. Clean the bolt and Breech Sensor.
Incorrectly seated rubber bolt tip. Re-seat the rubber bolt tip.
Damaged rubber bolt tip. Replace the rubber bolt tip.
The ETEK5 does not re.
The OOPS is not fully engaged. Twist the OOPS knob in until it engages.
The battery quality or charge level is very low. Install new high quality alkaline battery.
The battery is at. Replace the battery.
The dwell parameter is set too low. Increase the dwell parameter.
The trigger is set-up incorrectly. Set trigger up correctly. (see Advanced Set-Up Section)
The solenoid is not plugged into the ETEK5 PCB. Plug solenoid wire into port on the ETEK5 PCB.
The BS is enabled but there is no paint in the breech. Fill loader with paint.
The micro-switch is not being activated. Adjust trigger screws accordingly.
The PCB is damaged. Replace PCB.
The solenoid valve is damaged. Replace solenoid valve.