Manual
ETEK5 MANUAL 41
ADVANCED SL4 INLINE REGULATOR MAINTENANCE
This procedure is only required if your are xing a supercharging SL4 inline regulator
(common symptoms of supercharging are a very high velocity rst shot and/or large
variances in shot to shot consistency).
Place a 3/32” hex key through the adjuster top (see gure 23A), then insert a 1/8”
hex key into the bottom of the adjuster screw and carefully turn it counter-clockwise
until the two parts begin to unscrew freely (see gure 23B). With your ngers fully
unscrew the two parts taking care not to lose any of the internal components
(see gure 23C).
Inside the adjuster screw you will nd a regulator seal, purge poppet and spring
(purge poppet assembly) (see gure 23D). Inspect and clean the regulator seal,
turning it over if one side appears excessively worn or damaged or replace if
necessary. Inspect and clean the purge poppet or replace if necessary.
Place the purge poppet and attached spring in the central hole in the regulator
seal, then insert these parts into the adjuster screw (see gure 23E). Ensure is it re-
installed correctly, failure to do so may seriously damage the ETEK5 solenoid.
With the regulator seal, purge valve and spring installed back into the adjuster screw,
replace the adjuster top (see gure 23F). Screw the two parts tightly together using
1/8” and 3/32” hex keys. Refer to the ‘SL4 Inline Regulator Assembly’ section on
pages 39-40 to re-assemble the SL4 inline regulator.
WARNING!
Always de-gas your marker, discharging any stored gas in a safe direction,
and remove the barrel, loader, air system and any paintballs to make the
marker easier and safer to work on.
If you are unsure about performing a maintenance procedure please
contact your nearest service centre.
WARNING
FIG 23A
FIG 23C
FIG 23E
FIG 23B
FIG 23D
FIG 23F
MAINTENANCE