Manual
WARNING!
Always de-gas your marker, discharging any stored gas in a safe direction,
and remove the barrel, loader, air system and any paintballs to make the
marker easier and safer to work on.
Paintball industry standard eye/face/ear and head protection designed
specically to stop paintballs and meeting ASTM standard F1776 (USA)
or CE standard (Europe) must be worn by the user and any person within
range during use, assembly, cleaning and maintenance at all times.
WARNING
MAINTENANCE
A guide to performing routine
maintenance on your ETEK5.
ETEK5 MANUAL 37
CLEANING THE BREECH SENSOR (BS)
Undo the retaining screw for the Breech Sensor cover on the right hand side of
the ETEK5 using a 5/64” (2mm) hex key (see gure 21A).
Remove the cover to expose the back of the Breech Sensor (see gure 21B).
Using a dry cotton bud, carefully remove any debris, paint or moisture from the
back of the Breech Sensor and from inside the cover.
Lift the Breech Sensor free from the ETEK5 body and using another dry cotton
bud, remove any grease or debris build-up from the front of the Breech Sensor
(see gure 21C).
FIG 21A
FIG 21B
FIG 21C