Manual

USING THE ETEK5
24 ETEK5 MANUAL
THE TOURNAMENT LOCK
The ETEK5 has an electronic tournament lock which, once enabled, prevents
the user from making any changes to the set-up parameters of the marker.
This tournament lock complies with the rules of all major tournaments and must
be enabled prior to entering the eld of play in order to avoid penalties.
TO ENABLE THE TOURNAMENT LOCK -
1 Unscrew the two screws from the left hand side of the rubber grips
(see gure 17A) using a 5/64” hex key.
2 Turn on the ETEK5.
3 Locate and press the lock button on the circuit board (labelled
A
in gure 17B).
The LED on the navigation console will ash green to indicate that the tournament
lock has been enabled. If the OLED is tted then the LED will do nothing but the
lock indicator on the OLED display will show a closed padlock
.
4 Replace the two rubber grip screws using a 5/64” hex key.
TO DISABLE THE TOURNAMENT LOCK -
1 Unscrew the two screws from the left hand side of the rubber grips
(see gure 17A) using a 5/64” hex key.
2 Turn on the ETEK5.
3 Locate and press the lock button on the circuit board (labelled
A
in gure 17B).
The LED on the navigation console will ash red to indicate that the tournament
lock has been disabled. If the OLED is tted then the LED will do nothing but the
lock indicator on the OLED display will show an open padlock
.
4 Replace the two rubber grip screws using a 5/64” hex key.
FIG 17A
FIG 17B
A