Manual
(CONTINUED)
Inspect the sealing face of both the rammer housing
(SEE FIGURE 25G) and the exhaust valve (SEE
FIGURE 25H)
for any excessive wear or damage. If
either the exhaust valve or the rammer housing are
damaged then replace with authentic Etek4 parts.
Clean and lubricate all of the o-rings on the rammer
housing with Eclipse Gun Oil paying particular
attention to the front two around the outlet port on
the rammer housing
(SEE FIGURE 25I).
Insert the rammer housing back into the Etek4
body ensuring that the outlet port is facing upwards
and the valve plug hole is facing downwards
(SEE
FIGURE 25j)
.
Slide the rammer housing all the way into the Etek4
body until the rammer cap nears the back of the body.
Looking on the underside of the Etek4 body carefully
line up the hole in the body and rammer housing
which accommodates the valve plug screw
(SEE
FIGURE 25K).
IF YOU ARE AT ALL UNSURE OF PERFORMING A
MAINTENANCE PROCEDURE PLEASE CONTACT
YOUR NEAREST SERVICE CENTRE.
WARNING
FIG 25G
FIG 25H
FIG 25I
FIG 25K
FIG 25J
CONTENTS
ORIENTATION
QUICK SET-UP
USING THE ETEK4
ADVANCED SET-UP
EMORTAL BOARD
MAINTENANCE
UPGRADING
FAULT FINDING
SERVICE CENTRES
PARTS LIST
SPARES
INDEX
71.
MAINTENANCE
QUICK GUIDE