Manual
REMOVING AND ATTACHING
THE FRAME
Disconnect any hosing and unscrew the inline
regulator from the front regulator mount as detailed
in the Cleaning the Inline Regulator section of this
maintenance guide (pages 56-57).
Using a 5/64” hex key remove the six screws that
attach the Etek4 rubber grips to the Etek4 grip frame
(SEE FIGURE 22A). Unplug the solenoid
A
and
break beam sensor system connectors
B
from the
Etek4 circuit board
(SEE FIGURE 22B).
Using a 1/8” hex key undo the two frame retaining
screws
(SEE FIGURE 22C) and remove the frame
from the Etek4 body, taking care not to damage any
wires
(SEE FIGURE 22D).
You have now removed the frame.
DE-GAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER, AIR SYSTEM AND ANY
PAINTBALLS TO MAKE THE MARKER EASIER AND
SAFER TO WORK ON.
WARNING
FIG 22A
FIG 22b
FIG 22C
FIG 22D
A
B
64.
mAINTENANCE