Manual
CLEANING THE BREAK BEAM
SENSOR SYSTEM
Undo the retaining screw for the break beam sensor
cover on the left hand side of the Etek4 using a 5/64"
(2mm) hex key
(SEE FIGURE 16A).
Remove the sensor cover to expose the back of the
break beam sensor unit
(SEE FIGURE 16B). Using
a dry cotton bud, carefully remove any debris, paint or
moisture from the back of the sensor unit and from
inside the sensor cover.
Lift the BBSS free from the Etek4 body and using
another dry cotton bud, remove any grease or debris
build-up from the front of the sensor unit
(SEE
FIGURE 16C)
.
DE-GAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER, AIR SYSTEM AND ANY
PAINTBALLS TO MAKE THE MARKER EASIER AND
SAFER TO WORK ON.
WARNING
F IG 16 A
F IG 16 b
F IG 16 C
54.
mAINTENANCE