Manual

LOCK
THE TOURNAMENT LOCK PARAMETER
The Etek4 has a tournament lock which
prevents the user from making changes
to any parameter that affects the way in
which the Etek4 shoots without the use of
tools.
This parameter is used to set the state of
the tournament lock and has the following
choices:-
> ON:
Turn on the tournament lock.
The Set-Up Menu is only accessible by
removing the right hand cheek of the rubber grips and
then pressing and holding the red SETUP button on
the circuit board.
> OFF:
Turn off the tournament lock. The Set-Up
Menu is added to the Main Menu, making it easily
accessible by pressing and holding the
button.
> CANCEL: Cancel selection and leave the parameter
unchanged.
1
All presets are correct at time of printing. Please check with the
event organiser to make sure the above presets are still considered
legal.
2
The current preset configuration can be viewed from the run screen
by pressing the button.
3
Certain modes may only be available in certain countries and on
certain models of the Etek4.
PRESET
THE PRESET MENU
In order to simplify the set up of the Etek4 a number
of Preset configurations are available for selection.
Choosing one of these presets will cause all of the
necessary parameters to be set in such a way as to
make the Etek4 comply with the rules governing a
particular paintball league. It is also possible for the
user to save up to two Preset configurations of their
own.
1,2,3
LOAD
THE LOAD PRESET PARAMETER
This parameter is used to load the
required preset configuration and has the
following choices:
> USER 1: Load a set of custom firing mode
parameters that have been previously
saved by the user.
> USER 2: Load a set of custom firing mode
parameters that have been previously
saved by the user.
> FACTORY: Reset every parameter to the
factory set default. The Etek4 leaves the
factory set in this way.
> NPPL: Load a set of parameters that configures the
Etek4 to comply with the 2008 NPPL rules governing
firing modes.
1
> PSP 10: Load a set of parameters that configures the
Etek4 to comply with the PSP rules governing firing
modes in lower divisions (10bps).
1
> PSP 12: Load a set of parameters that configures the
Etek4 to comply with the PSP rules governing firing
modes in higher divisions (12bps).
1
> MS10: Load a set of parameters that configures the
Etek4 to comply with the 2009 Millennium Series
rules governing firing modes.
1
> CANCEL: Editing is cancelled and the parameter
remains unchanged.
CONTENTS
ORIENTATION
QUICK SET-UP
USING THE ETEK4
ADVANCED SET-UP
EMORTAL BOARD
MAINTENANCE
UPGRADING
FAULT FINDING
SERVICE CENTRES
PARTS LIST
SPARES
INDEX
47.
EMORTAL BOARD
QUICK GUIDE