Manual

The remaining set up parameters are used to
configure the performance of the Etek4.
DWELL
The Dwell parameter controls the
amount of time that the solenoid
is energised and therefore the
amount of gas that is released
with each shot.
The Dwell parameter is indicated
by a purple light on the navigation
console when you are in the Set
Up mode.
This parameter is fully adjustable between 1.0ms and
15.0ms in 0.1ms increments.
DEBOUNCE
The Debounce parameter is used
to set the level of Debounce (anti
trigger bounce) on your Etek4.
The Debounce parameter is
indicated by a ‘light blue’ light on
the navigation console when you
are in the Set Up mode.
This parameter is fully adjustable
between Debounce 1 and Debounce 9 with a higher
value reducing the amount of trigger bounce.
THE BALL
DETECTION TIME
The Ball Detection Time parameter
defines how long a paintball has
to sit in the breech of the Etek4
before it is considered ready to fire.
The Ball Detection Time parameter
is indicated by a yellow light on the
navigation console when you are in
the Set Up mode.
This parameter is fully adjustable between 1 ms and
10 ms in 1 ms increments.
THE RESET PARAMETER
Whilst in Set Up Mode, it is
possible to reset all of the control
parameters to the factory default
settings in the following way:
1. Push and hold the Lock button
for two seconds.
2. The “E”, “G” and “O” on the
navigation console will repeatedly
flash blue to indicate that the
factory default settings have been
restored.
34.
ADVANCED SET-UP