Manual

THE SET UP MODE
The Set Up Mode can only be entered if tournament lock
is off. See page 29 for details on the tournament lock.
To activate the Set Up Mode, firstly ensure that the Etek4
is switched off. Pull and hold the trigger, and whilst the
trigger is still pulled push and hold the
button until
the ‘E’ and the ‘O’ on the navigation console alternately
flash white to indicate entry to Set Up mode. When you
have entered the Set Up mode, the ‘G’ on the navigation
console will turn red to indicate the first parameter of the
Set Up Mode. You can now release the trigger.
Press the
button to scroll through each of
the parameters on the Set Up Mode:
To see the value that any setup parameter is set to, pull
and release the trigger. The value will be indicated by
flashing the tens on the ‘E’ LED, the units on the ‘G’ LED
and tenths on the ‘O’ LED. E.g. 14.5 would be indicated
as follows-
- 1 FLASH OF THE ‘E’ LED
- 4 FLASHES OF THE ‘G’ LED
- 5 FLASHES OF THE ‘O’ LED
A zero is indicated by no flashes. E.g. 3.0 would be
indicated as follows:
- 0 FLASHES OF THE ‘E’ LED
- 3 FLASHES OF THE ‘G’ LED
- 0 FLASHES OF THE ‘O’ LED
MODIFYING A PARAMETER
You can modify a parameter by using the following
guidelines.
1. Ensure that you are in Set Up mode.
2. Choose the parameter that you wish to modify by
pressing
until G turns to the parameter colour.
3. Pull and hold the trigger for 1 second. The ‘E’ LED will
light up.
4. Set the tens digit by pressing the trigger once for each
ten, the ‘E’ LED will flash with each trigger pull. DO NOT
pull the trigger if the required digit is zero.
5. Push the
button. The ‘G’ LED on the navigation
console is illuminated.
6. Set the units digit by pressing the trigger once for each
unit, the ‘G’ LED will flash with each trigger pull. DO NOT
pull the trigger if the required digit is zero.
7. Push the button. The ‘O’ on the navigation console
is illuminated.
8. Set the units digit by pressing the trigger once for each
unit, the ‘O’ LED will flash with each trigger pull. DO NOT
pull the trigger if the required digit is zero.
9. Push the button. The “E”, “G” and “O” will flash
three times; if the colour is green then the value has been
accepted and saved, if the value is red then the value has
been rejected and restored to its value before modifying.
For example to set a parameter to 14.5 -
- PULL THE TRIGGER 1 TIME WHILE THE ‘E’ LED IS LIT
THEN PRESS
- PULL THE TRIGGER 4 TIMES WHILE THE ‘G’ LED IS LIT
THEN PRESS
- PULL THE TRIGGER 5 TIMES WHILE THE ‘O’ LED IS LIT
THEN PRESS
To leave a parameter unchanged having already started
to modify it, simply set an illegal value (any single
digit greater than 9) and the value will consequently be
rejected.
COLOUR
PARAMETER
RANGE
Red
Green
Blue
White
Dark Red
Purple
Light Blue
Yellow
Firing Mode
Maximum ROF with
BBSS on (capped
modes only).
Dwell
Debounce
Ball Detection Time
1 to 3
4.0 bps to 15.4
bps
4.0 bps to 15.4
bps
5.0 pps to 10.0
pps
1.0 ms to 15.0 ms
0.0 to 1.0 s
1 to 10
1 ms to 10 ms
Maximum ROF
with BBSS off.
Ramp Kick-in Rate
(ramp only)
Ramp Restart
Time (ramp only)
CONTENTS
ORIENTATION
QUICK SET-UP
USING THE ETEK4
ADVANCED SET-UP
EMORTAL BOARD
MAINTENANCE
UPGRADING
FAULT FINDING
SERVICE CENTRES
PARTS LIST
SPARES
INDEX
31.
ADVANCED SET-UP
QUICK GUIDE