Manual
CONTINUED
INSTALLING THE FRAME
To install a upgrade metal frame to your Etek3 LT rst
remove your GRN frame. See Removing and Attaching the
Frame on page 61-62. Next remove the battery (See page
10 on Installing a 9V Battery).
Remove the OOPS from the GRN frame by loosening the
two retaining screws with a 3/32” hex key SEE FIGURE
24.1
. Then slide the OOPS o the T-slot.
Remove the trigger assembly from the GRN frame as
detailed in ‘The Etek3 Trigger Assembly’ section of the
maintenance chapter (See page 63-64).
Remove the trigger retaining clip that holds the micro-
switch in place on the frame SEE FIGURE 24.2, then
unplug the micro-switch from the Etek3 circuit board. Slide
the circuit board and clips out of the frame SEE FIGURE
24.3.
Screw the micro-switch into place on the metal frame
using the two Phillips M2x10 screws provided SEE
FIGURE 24.4.
Install the trigger assembly into the metal frame as covered
in ‘The ETEK3 Trigger Assembly’ (See page 63-64).
If the Emortal board is also being installed at this point
please turn to page 75 - ‘Installing the Emortal Board’.
Attach the circuit board retaining clips to the Etek3 circuit
board, ensuring when inserting it into the frame that the
clips are in the correct orientation as shown in FIGURE
24.5.
Slide the circuit board and retaining clips into the
metal frame SEE FIGURE 24.6.
Insert and connect the battery (See page 10).
Slide the OOPS onto the metal frame and tighten down the
retaining screws using a 3/32” hex key.
Attach the frame to the Etek3 body as covered on page 62
FIG 24.1 FIG 24.2
FIG 24.4
FIG 24.6FIG 24.5
FIG 24.3
ETEK3 LED BOARD
ORIENTATION
WARNING: IF YOU ARE AT ALL UNSURE OF PERFORMING
THE MAINTENANCE PROCEDURE PLEASE CONTACT
YOUR NEAREST ECLIPSE SERVICE CENTRE. SEE PAGES
8081
WARNING
CONTENTS
ORIENTATION
QUICK SET-UP
USING YOUR ETEK3
ADVANCED SET-UP
EMORTAL BOARD
MAINTENANCE
UPGRADING
FAULT FINDING
SERVICE CENTERS
PARTS LIST
SPARES & ACCESSORIES
INDEX
73.
UPGRADING
UPGRADING
QUICK GUIDE