Manual
THE ETEK3 SOLENOID
ASSEMBLY
With the frame separated from the Etek3 body and the
solenoid assembly and BBSS assembly unplugged from the
circuit board (see page 63) SEE FIGURE 20.1, use a small
Phillips head screw driver to undo and remove the two
M1.6x16 screws that hold the solenoid assembly onto the
solenoid manifold SEE FIGURE 20.2.
Removing the solenoid will completely reveal the solenoid
manifold SEE FIGURE 20.3, using a 5/64 hex key remove
all three M2.5x5 screws which hold the manifold to the
Etek3 body SEE FIGURE 20.4.
With the solenoid assembly completely removed from
the Etek3 body the bottom of the Etek3 body should now
resemble FIGURE 20.5. Ensure that the air transfer holes
in the bottom of the body are free from contamination
from any dirt, debris, paint or moisture and clear away
any excess grease if it appears to be blocking any of the
transfer holes.
Check the top and bottom of the solenoid manifold to
ensure that it is also free from damage or debris
SEE
FIGURE 20.5
. Remove and clean the rubber gaskets
as shown in FIGURE 20.6. Replace the rubber gaskets
ensuring that they lie at in their designated grooves in the
solenoid manifold body.
Re-attach the solenoid manifold to the Etek3 body with the
three M2.5x5 screws.
FIG 20.2
FIG 20.3
FIG 20.4
FIG 20.5
FIG 20.7
FIG 20.6
FIG 20.1
WARNING: DEGAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE THE
BARREL, LOADER, AIR SYSTEM AND ANY PAINTBALLS TO
MAKE THE MARKER EASIER AND SAFER TO WORK ON.
WARNING
CONTENTS
ORIENTATION
QUICK SET-UP
USING YOUR ETEK3
ADVANCED SET-UP
EMORTAL BOARD
MAINTENANCE
UPGRADING
FAULT FINDING
SERVICE CENTERS
PARTS LIST
SPARES & ACCESSORIES
INDEX
65.
MAINTENANCE
MAINTENANCE
QUICK GUIDE