Manual

RATE
THE LINEAR RAMP RATE PARAMETER
The parameter is only available when LINEAR
Ramping is selected and is used to set the
percentage increase in rate of re over rate of
trigger pulls.
For example, if the user is pulling the trigger
at a rate of 10 pulls per second and the
RATE
parameter is set to 50% then the rate of re is
10 plus 50% extra which is 15 balls per second.
This parameter can be set between 0 and
100% in 10% increments.
PULL NO
THE RAMP START PARAMETER
The parameter sets the number of trigger pulls
that are required at the KICK IN rate before
ramping will start. The parameter can be set
between 4 and 9 pulls in increments of 1.
KICK IN
THE RAMP KICKIN PARAMETER
This parameter sets the minimum rate at
which the user has to pull the trigger in order
to start ramping. This parameter can be set
between 5.0 and 15.0 pulls per second in 0.1
pulls per second increments.
SUSTAIN
THE SUSTAIN RATE PARAMETER
Once the Etek3 is ramping the user has to
continue to pull the trigger at a minimum
rate in order to maintain the ramping. This
parameter sets this rate and can be between
5.0 and 15.0 pulls per second in 0.1 pulls per
second increments.
RESTART
THE RAMP RESTART PARAMETER
The RESTART parameter denes the amount
of time after the last trigger pull during which
the ramp can be restarted with a single trigger
pull. If a trigger pull occurs after the RESTART
time has expired, then the other ramp start
conditions have to be met before ramping will
restart. This parameter can be set between 0.0
and 1.0 seconds in 0.1 second increments.
48.
EMORTAL BOARD
48.
EMORTAL BOARD