Manual
RAMP KICKIN
RATE
RAMP ONLY
The RAMP KICKIN RATE parameter sets
the rate at which the trigger has to be
pulled in order to start and maintain
ramping.
The RAMP KICKIN RATE parameter is
indicated by a white light on the Navigation Console when
you are in the SET UP mode.
This parameter can be set between 5.0 and 10.0 pulls per
second in 0.1 pps increments.
RAMP RESTART
TIME
RAMP ONLY
The RAMP RESTART TIME parameter sets
the time during which ramping can
be restarted with a single trigger pull,
after the previous ramping string has
stopped.
The parameter is specied in seconds and if set to 0.0 then
ramping can only be restarted with four shots at the RAMP
KICKIN RATE.
The RAMP RESTART TIME parameter is indicated
by a dark red light on the Navigation Console when you are
in the SET UP mode.
This parameter is fully adjustable between 0.0 and 1.0
seconds.