Manual
SET UP PARAMETERS
The rst ve set up parameters will need to be set to
comply with the rules of the eld or site at which this Etek3
is used. It is the user’s responsibility to ensure that these
parameters are correctly set.
THE FIRING
MODE
PARAMETER
This parameter is used to control the
ring mode of the Etek3. The FIRING
MODE
parameter is indicated by a red
light on the Navigation Console when
you are in the SET UP mode. There
are three selectable FIRING MODES as
outlined below:
1.0 : UNCAPPED SEMI
In this mode the Etek3 will re one shot for every pull of
the trigger. This mode is uncapped with the BBSS enabled.
If the BBSS is o then the rate of re is limited by the
MAXIMUM ROF WITH BBSS OFF parameter.
2.0 : CAPPED SEMI
This mode is the same as the UNCAPPED SEMI mode, except
that the rate of re is capped to the MAXIMUM ROF WITH
BBSS ON
parameter.
3.0 : CAPPED RAMP
This mode allows the rate of re to ramp to a maximum
set by the MAXIMUM ROF WITH BBSS ON parameter, once
the trigger is being pulled at the required pulls per second
rate set by the RAMP KICKIN RATE parameter. The number of
trigger pulls has to remain equal or above the RAMP KICKIN
RATE
parameter to continue ramping. After the last trigger
pull, the ramp can be restarted with a single trigger pull
within the time set in the RAMP RESTART TIME parameter.
Certain modes may only be available in certain countries
and on certain models of the Etek3.
THE MAXIMUM
ROF WITH BBSS
ON
CAPPED MODES
In capped ring modes this parameter
is used to control how fast the Etek3
can cycle.
The MAXIMUM ROF WITH BBSS ON
parameter is indicated by a green light on the Navigation
Console when you are in the SET UP mode.
This is fully adjustable between 4.0 balls per second and
15.4 balls per second in 0.1 bps increments.
THE MAXIMUM
ROF WITH BBSS
OFF
This parameter is used to control
how fast the Etek3 cycles when the
Break Beam Sensor System has been
disabled.
The MAXIMUM ROF WITH BBSS OFF
parameter is indicated by a blue light on the Navigation
Console when you are in the SET UP mode.
This parameter is fully adjustable between 4.0 balls per
second and 15.4 balls per second in 0.1 bps increments.
This parameter should be set to match the slowest speed
of the loading system in use.
28.
ADVANCED SET-UP