SYMPTOM POSSIBLE CAUSE SOLUTION
Two or more balls are beinng fed into the
breech.
Etek2 is inconsistent.
Leaking Rammer Assembly ( Leak gets louder
when bolt is removed ).
How can I get the best performance out of
my gun?
BBSS turns itself off after firing.
OOPS leaks from front hole (nearest on/off
knob).
OOPS leaks from rear hole (nearest Tank).
If the Etek2 is being used with a force feed
loader, it is possible that the loader is forcing
balls past the ball detent.
Inline Regulator is supercharging.
Front ram shaft seal deteriorated.
Check your set-up.
Eye is dirty.
Eye is faulty.
Eye is out of place.
006 NBR 90 O-Ring too dry.
006 NBR 90 O-Ring damaged.
Tank O-Ring is damaged.
Check that the sensors face each other when
installed.
Change the rubber finger detents.
Strip and clean Inline Regulator ( See
Maintenance Section ).
Replace front Rammer Shaft seal.
Using a force-fed loader ( Halo B, VLocity,
Pulse) with the Break-Beam Sensor System
enabled will give the highest peformance.
Clean the eyes.
Replace the eyes.
Re-Install Eyes. Check alignment.
Lubricate 006 NBR 90 O-Ring with Eclipse Oil.
Replace 006 NBR 90 O-Ring.
Replace the Tank O-Ring.