Manual
VISIT WWW.PLANETECLIPSE.COM
FAULT FINDING
40
VISIT WWW.PLANETECLIPSE.COM
SYMPTOM POSSIBLE CAUSE SOLUTION
Low Velocity First Shot.
High Velocity First Shot.
My Trigger is very “Bouncy”, how can I reduce
it?
The Break-Beam Sensor System does not
appear to be reading correctly.
The Break-Beam Sensor System is not
reading at all.
DWELL parameter is too low to overcome
stiction on Solenoid and / or Rammer O-rings.
DWELL parameter set too high.
Inline Regulator pressure creeping.
Too low Debounce setting.
Lengthen and strengthen your trigger pull.
The Break-Beam Sensor System is dirty.
Break-Beam Sensors are the wrong way
around.
There is a broken wire or contact, or a short
circuit on either of the Breech Sensor ribbon
cables.
Either sensor is back to front.
Increase DWELL parameter.
Reduce DWELL parameter.
Strip and clean Inline Regulator. Replace Inline
Regulator piston if necessary.
Increase Debounce setting.
Refer to Advanced Set-Up Section for
guidelines of how to adjust your Etek2 Trigger
accordingly.
Keep the Break-Beam Sensors clean to
ensure correct readings ( See Maintenance
Section ).
Check that the red receiver is on the right-
hand side of the Breech.
Check the plug of the cables.
Check for cuts or pinches in the sensor
cables.
Check that the sensors face each other when
installed.