ThE firiNg mOdE
paramETEr.
TheFiringModeParameterisusedtocontroltheringmodeoftheEtek
Ego. The Firing Mode Parameter is displayed by a Red light on the Control
Console when you are in the Set Up Menu. There are ve
selectable Firing Modes on the Etek Ego. Each of the selectable
ringmodeshasitsownfeaturesasoutlinedbelow:
sEmi 1
(Mode1ontheFiringModeParameter)
This is the default ring mode which produces one shot for
every pull of the the trigger. This mode is uncapped with the
BreakBeamSensorSystem(BBSS)enabled.
sEmi 2
(Mode2ontheFiringModeParameter)
ThismodeisthesameasSemi1mode,exceptforthefactthat
therateofreiscappedat15ballspersecond(bps).
ramp 1
(Mode3ontheFiringModeParameter)
ThismodeallowstherateofretoramptoamaximumsetbytheMaximum
Rate of Fire with BBSS enabled parameter, once the trigger has been pulled
fourtimesataminimumrateof5pps(pullspersecond),andallowsthisrate
ofretomaintainedaslongastherequiredtriggerpullrateismaintained.
After the last trigger pull, the ramp can be restarted with a single trigger pull
if that pull occurs within one second.
ramp 2
(Mode4ontheFiringModeParameter)
ThismodeisthesameasRamp1modebutwithouttheonesecondramp
restart.
ramp 3
(Mode5ontheFiringModeParameter)
This mode is the same as Ramp 2 mode but activates at a minimum rate of
7.5pullspersecond.
Please Note: Certain modes may only be available in certain countries and
on certain models of the Etek Egos.
ThE maximum raTE Of
firE (cappEd mOdEs).
The Maximum Rate of Fire in capped modes is used to control how fast
theEtekEgocancycleineachofthecappedringmodes;
Semi2,Ramp1,Ramp2andRamp3.
TheMaximumRateofFire(cappedmodes)Parameteris
displayed by a Green light on the Control Console when
you are in the Set Up Menu.
Thisisfullyadjustablebetween10.0ballspersecondand
15.4ballspersecondin0.1bpsincrements.
ThE maximum raTE Of
firE (bbss disablEd).
The Maximum Rate of Fire with the BBSS disabled is used to control how
fast the Etek Ego cycles when the Break Beam Sensor
System has been disabled.
TheMaximumRateofFire(BBSSdisabled)Parameteris
displayed by a Blue light on the Control Console when you
are in the Set Up Menu.
Thisparameterisfullyadjustablebetween10.0ballsper
secondand15.4ballspersecondin0.1bpsincrements.
This parameter should be set to match the slowest speed
of the loading system in use.
dwEll.
The Dwell Parameter controls the amount of time that the solenoid is
energised and therefore the amount of gas that is released with each shot.
The Dwell Parameter is displayed by a Purple light on the
Control Console when you are in the Set Up Menu.
Thisparameterisfullyadjustablebetween1.0msand15.0ms
in0.1msincrements.
dEbOuNcE.
TheDebounceParameterisusedtosetthelevelofDebounce(anti-bounce)
on your Etek Ego.
The Debounce Parameter is displayed by a Light Blue light on
the Control Console when you are in the Set Up Menu.
This parameter is fully adjustable between Debounce 1 and
Debounce10withDebounce1allowingthemostbounceand
Debounce10theleast.
ThE ball dETEcTiON
TimE.
TheBallDetectionTimeParameterdeneshowlongapaintballhastositin
thebreechoftheEtekEgobeforeitisconsideredreadytore.
The Ball Detection Time Parameter is displayed by a Yellow light
on the Control Console when you are in the Set Up Menu.
Thisparameterisfullyadjustablebetween1msand10msin1
ms increments.
ThE rEsET
paramETEr.
Whilst in Set Up Mode, it is possible to reset all of the control
parameters to the factory default settings in the following way:
1.PushandholdtheLockpushbutton(SEEFIGURE4.5)
2.The“E”,“G”and“O”onthecontrolwillrepeatedlyashblue
to indicate that the factory default settings have been
restored.
3. Release the Lock pushbutton.