Manual
SYMPTOM POSSIBLE CAUSE SOLUTION
TheEtekEgodoesnotre.
LowVelocityFirstShot.
HighVelocityFirstShot.
Trigger is set up incorrectly.
Solenoid is not plugged into the Etek Ego
PCB.
TheBreak-BeamSensorSystemisenabled
but there is no paint.
DWELL parameter is too low to overcome
stictiononSolenoidand/orRammerO-rings.
DWELL parameter set too high.
Inline Regulator pressure creeping.
Settriggerupcorrectly(SeeAdvancedSet-
UpSection).
Plug solenoid into port on the Etek Ego PCB.
Fill loader with paint / switch off BBSS.
Increase DWELL parameter.
Reduce DWELL parameter.
Strip and clean Inline Regulator. Replace Inline
Regulator piston if necessary.
SYMPTOM POSSIBLE CAUSE SOLUTION
My Trigger is very “Bouncy”, how can I reduce
it?
TheBreak-BeamSensorSystemdoesnot
appear to be reading correctly.
TheBreak-BeamSensorSystemisnot
reading at all.
Two or more balls are beinng fed into the
breech.
Too low Debounce setting.
Lengthen and strengthen your trigger pull.
TheBreak-BeamSensorSystemisdirty.
Break-BeamSensorsarethewrongway
around.
There is a broken wire or contact, or a short
circuit on either of the Breech Sensor ribbon
cables.
Either sensor is back to front.
If the Etek Ego is being used with a force feed
loader, it is possible that the loader is forcing
balls past the ball detent.
Increase Debounce setting.
RefertoAdvancedSet-UpSectionfor
guidelines of how to adjust your Etek Ego
Trigger accordingly.
KeeptheBreak-BeamSensorscleanto
ensurecorrectresdings(SeeMaintenance
Section).
Checkthattheredreceiverisontheright-
hand side of the Breech.
Check the plug of the cables.
Check for cuts or pinches in the sensor
cables.
Check that the sensors face each other when
installed.
Changetherubberngerdetents.
VIsIT www.PlAneTeclIPse.coM
36
faulT fiNdiNg
VIsIT www.PlAneTeclIPse.coM
37
faulT fiNdiNg