Manual

17
EMEK
MAINTENANCE
FAULT FINDING TABLES
SYMPTOM POSSIBLE CAUSE SOLUTION
The EMEK does not re.
The air system is not fully engaged. Screw in the air system until it fully engages.
The three-way is damaged. Replace the three-way.
Low constant velocity. The inline regulator output pressure set too low. Increase the output pressure of the inline regulator.
High velocity rst shot. The inline regulator pressure is creeping.
Strip and clean the inline regulator replacing the regulator
seal inside the regulator adjuster assembly.
Velocity drop-off during rapid re.
Air system regulator does not have high enough ow. Try another air system.
Dirty/partially blocked inline regulator. Strip, clean, lubricate and rebuild the inline regulator.
Two or more balls are being
fed into the breech.
Worn, damaged or missing ball detents. Change the rubber ball detent.
The feed force too high from loader. Adjust loader settings/use lower force loader.
EMEK is inconsistent.
The inline regulator is dirty. Strip and clean inline regulator, replace regulator seal.
Poor quality paintballs. Use better quality paintballs.
Poor paintball size to barrel bore match. Use a closer paintball to barrel bore size.
Inconsistent air supply from air system. Service the air system.
EMEK is inefcient. Poor paintball size to barrel bore match Use a closer paintball to barrel bore size.
If an issue with the EMEK cannot be solved using the fault nding guide, contact your nearest Eclipse Service Centre for assistance.