Manual
Before using the Ego LV1 it is important to make sure the
SL4 inline regulator, low pressure regulator, solenoid flow
restrictors (SFR) and all electronically controlled parameters
are set correctly. All of these can have a negative effect on
the performance of the marker if set incorrectly.
The steps below will restore the Ego LV1 settings to the
factory settings. These settings will give the Ego LV1 a more
balanced performance, ideal for the average user.
Inline Regulator Output Pressure
Check the inline regulator adjuster screw is set to
3 turns clockwise from its maximum out position
(SEE FIGURE
1A)
. This will ensure the SL4 inline regulator is set to an
output pressure that will not damage the Ego LV1 when
supplied with compressed air/nitrogen (see page 18 for more
information on SL4 inline regulator adjustment).
LPR Output Pressure
Insert a 1/8” hex key into the LPR adjuster screw
(SEE FIGURE
1B)
.
Gently screw the adjuster clockwise until a small amount
of resistance is met. Now screw the adjuster counter-clockwise
1 turn. This is the factory LPR setting, see page 18 for more
information on LPR adjustment.
Solenoid Flow Restrictor Settings
Check that the SFRs
(SEE FIGURE 1C)
are set to the following
levels; return restrictor
A
to level 5, forward restrictor
B
to
level 7. To access the SFRs, unscrew and peel away the right
side of the grips. See page 19 for more information on the
solenoid flow restrictors.
Electronically Controlled Parameters
Load the FACTORY preset
(SEE FIGURE 1D)
stored on the Ego
LV1 circuit board. This preset will restore all the electronic
parameters to their default settings. See page 29 on loading
the FACTORY preset.
FACTORY SET-UP GUiDE
FIG 1A
FIG 1B
FIG 1C
FIG 1D
DE-GAS YOUR MARKER, DISCHARGING ANY STORED GAS IN
A SAFE DIRECTION, AND REMOVE THE BARREL, LOADER, AIR
SYSTEM AND ANY PA INTBALLS TO MAKE THE MARKER
EASIER AND SAFER TO WORK ON.
WARNING
A
B
6 USiNG THE EGO LV1