Manual
(CONTiNUED)
Position the trigger so that the hole through the trigger lines
up with the holes in the bearing carrier, slide the trigger pin
into place
(SEE FIGURE 24G)
.
Gently lower the trigger assembly and bearing carrier into
the frame, taking care not to damage the micro-switch or
the OPTO sensor, and ensuring that the trigger is positioned
correctly
(SEE FIGURE 24H)
.
Using a 5/64” hex key screw the right side M2.5x5 retaining
screw into place but do not fully tighten it into place
(SEE
FIGURE 24I)
.
Ensure the trigger moves freely within the frame, then using a
1/16” hex key tighten down the trigger pin retaining set screw.
Place the trigger spring over the bearing carrier in its
designated groove, align the hole in the trigger spring with the
front/left hole in the bearing carrier, then screw the retaining
screw into the frame. Tighten both screws with a 5/64” hex
key
(SEE FIGURE 24J)
.
DO NOT OVERTIGHTEN THE RETAINING SCREWS. DOING SO
MAY DAMAGE THE TRIGGER SPRING AND THREADS IN THE
FRAME.
You have now stripped and cleaned your Ego LV1 trigger
assembly.
IF YOU ARE UNSURE ABOUT PERFORMING A MAINTENANCE
PROCEDURE PLEASE CONTACT YOUR NEAREST SERVICE
CENTRE.
WARNING
FIG 24G
FIG 24H
FIG 24I
FIG 24J
MAiNTENANCE 55