Manual
95% of trigger bounce problems can be eliminated by utilizing one of the nine fixed
DEBOUNCE
choices (LEVEL 1-9). In
attempting to eliminate trigger bounce it is advisable to try the nine fixed
DEBOUNCE
choices before attempting any advanced
set up of the trigger filters.
This menu comprises parameters that control low level functionality of the Ego LV1 electronic hardware.
In order to optimize the trigger filters it is necessary to have the
PULL PT
parameter set as high as possible and the
RELEASE PT
parameter set as low as possible:
1. Select the
PULL PT
parameter. Observe that the graphical bar rises and falls as the trigger is pulled and released. The actual
value of the graphical bar is displayed in the top right of the display.
2. Set the rear stop screw as required, ensuring that the bar is as close to 100% as possible when the trigger is fully depressed
against the set screw. It is advisable to allow for some extra travel in the trigger pull once the bar has reached its maximum value.
3. Adjust the
PULL PT
parameter so that when the trigger is fully depressed the bar settles above the indicator on the left hand
side of the screen (see page 35).
4. Select the
RELEASE PT
parameter. Observe that the graphical bar rises and falls as the trigger is pulled and released. The actual
value of the graphical bar is displayed in top right of the display.
5. Set the front stop screw as required, ensuring that the bar is as close to 0% as possible when the trigger is fully released
against the set screw. It is advisable to allow for some extra travel in the trigger release once the bar has reached its minimum
value.
6. Adjust the
RELEASE PT
parameter so that when the trigger is fully released the bar settles beneath the indicator on the left hand
side of the screen (see page 35).
7. Set the magnet return strength screw and the spring return strength screw as required, making both the spring tension and the
return force as strong as possible without compromising the “feel” of the trigger.
BASiC TRiGGER FiLTER SET-UP
HARDWARE
MENU
ADVANCED TRiGGER FiLTER SET-UP
36 ADVANCED SETUP