Manual

The Ego LV1 is fitted with a dual trigger pull detection system. A non-contact OPTO-electronic trigger sensor
arrangement is used to detect trigger movement whilst a micro-switch is used to provide a more traditional tactile
feedback for the trigger. The
TRIGGER
parameter is used to select which system is used. The choices available are
as follows:
> OPTO: Select the OPTO sensor for trigger pull detection.
> SWITCH: Select the micro-switch for trigger pull detection.
> CANCEL: Cancel editing and leave the parameter unchanged.
TRiGGER
PARAMETER
This parameter controls the amount of power used by the solenoid valve and should normally be left at it’s default
‘LO PWR’ setting. Cold weather (sub 0°
C
/32°
F
) will cause lubricants to thicken and increase stiction in the marker
system which may cause velocity drop-off and/or shot to shot inconsistency. Increasing the solenoid power will often
help to eliminate these problems, but will cause more drain on the battery. The choices available for the parameter
are:-
> LO PWR: Low power solenoid drive
> HI PWR: High power solenoid drive
> CANCEL: Cancel editing and leave the parameter unchanged
The Ego LV1 board is capable of emitting a variety of sounds to audibly signal when certain functions have been
performed including, but not limited to, powering up, powering off, changing the BBSS mode and resetting various
counters and timers. This parameter determines if this feature is switched on or off. Switching it on will cause
increased drain on the battery. The choices available for this parameter are:
>OFF: Sounds switched off.
>ON: Sounds switched on.
>CANCEL: Cancel editing and leave the parameter unchanged.
This parameter determines if the Ego LV1 emits a tone each time any of the pushbuttons on the navigation console
are activated. As part of the smart menu system the
TONES
parameter will only be shown in the
HARDWARE
menu if
the
SOUND
parameter is switched ‘ON’. The choices available for this parameter are:
>OFF: Tones switched off.
>ON: Tones switched on.
>CANCEL: Cancel editing and leave the parameter unchanged.
SOLENOiD
PARAMETER
SOUND
PARAMETER
TONES
PARAMETER*
ADVANCED SETUP 37