Manual

The parameters on the
FILTER
menu are all used to tune the Ego LV1’s software filters which prevent the Ego LV1
from firing unless all of the necessary conditions are met. The factory default settings will be suitable for most set-
ups, however certain loader and trigger set-ups may require modification of one or more of these parameters.
FiLTER
MENU
The
DEBOUNCE
parameter is used to combat any trigger bounce that might occur in the Ego LV1 and can be set
between level 1 and level 9 in one level increments.
> LEVEL 9: Level 9 providing the most filtering (least ‘bouncy’).
> LEVEL 1: Level 1 providing the least filtering (most ‘bouncy’).
> CANCEL: Cancel editing and leave the parameter unchanged.
In order for the BBSS to function correctly it must first detect that the bolt is fully retracted and the breech
is empty, and then detect that a paintball is loaded into the breech before the Ego LV1 is allowed to fire. The
parameter can be set between 1.0 and 20.0ms in 0.1ms increments.
Tumbling paintballs can take time to settle in the breech before they can be successfully fired. This parameter is
used to set the amount of time that a paintball has to be in the breech before the Ego LV1 is allowed to fire. This
parameter can be set between 1.0 and 20 milliseconds in 0.1ms increments.
DEBOUNCE
PARAMETER
EMPTY
PARAMETER
FULL
PARAMETER
34 ADVANCED SETUP