ADVANCED TRIGGER
FILTER SET-UP
In order to optimize the Trigger filters it is necessary to
have the PULL PT parameter set as high as possible and
the RELEASE PT parameter set as low as possible:
1. Select the PULL PT parameter. Observe that the
graphical bar rises and falls as the trigger is pulled
and released. The actual value of the graphical bar is
displayed in the top right of the display.
2. Set the Rear Stop Trigger Screw as required, ensuring
that the bar is as close to 100% as possible when the
trigger is fully depressed against the set screw. It is
advisable to allow for some extra travel in the trigger pull
once the bar has reached its maximum value.
3. Adjust the PULL PT parameter so that when the
trigger is fully depressed the bar settles above the
indicator on the left hand side of the screen (see page
42).
4. Select the RELEASE PT parameter. Observe that the
graphical bar rises and falls as the Trigger is pulled
and released. The actual value of the graphical bar is
displayed in top right of the display.
5. Set the Front Stop Trigger Screw as required,
ensuring that the bar is as close to 0% as possible when
the trigger is fully released against the set screw. It is
advisable to allow for some extra travel in the trigger
release once the bar has reached its minimum value.
6. Adjust the RELEASE PT parameter so that when the
trigger is fully released the bar settles beneath the
indicator on the left hand side of the screen (see page
42).
7. Set the Magnet Return Strength Screw and the Spring
Return Strength Screw as required, making both the
spring tension and the return force as strong as possible
without compromising the “feel” of the trigger.
HARDWARE
THE HARDWARE MENU
This menu comprises parameters that control low level
functionality of the Ego11 electronic hardware.
TRIGGER
THE TRIGGER DETECTION PARAMETER
The Ego11 is fitted with a dual trigger
pull detection system. A non-contact
Opto-electronic trigger sensor
arrangement is used to detect Trigger
movement whilst a Micro-switch is used
to provide a more traditional tactile
feedback for the Trigger. The TRIGGER
parameter is used to select which system
is used. The choices available are as
follows:
> OPTO: Select the Opto sensor for trigger pull
detection.
> SWITCH: Select the Micro-switch for trigger pull
detection.
> CANCEL: Cancel editing and leave the parameter
unchanged.
(CONTINUED OVERLEAF)