User's Manual
THE EGO10 SOLENOID
ASSEMBLY
With the frame separated from the Ego10 body and the
solenoid assembly and BBSS assembly unplugged from the
circuit board (see page 57) use a 5/64” hex key to undo and
remove the two screws that hold the solenoid assembly
onto the Ego10 body SEE FIGURE 16.1.
With the solenoid assembly completely removed from the
Ego10 body the bottom of the Ego10 body should now
resemble FIGURE 16.2 Ensure that the air transfer holes
in the bottom of the body are free from contamination
from any dirt, debris, paint or moisture and clear away
any excess grease if it appears to be blocking any of the
transfer holes.
Check the underside of the solenoid assembly to ensure
that it is also free from damage or debris
SEE FIGURE
16.3
. Remove and clean the rubber gasket as shown in
FIGURE 16.4. Replace the rubber gasket ensuring that it
lies at in its designated groove in the solenoid manifold
body SEE FIGURE 16.5.
If you are replacing a defective pilot valve, unscrew it from
the solenoid manifold and replace it with a new pilot valve
unit
SEE FIGURE 16.6.
WARNING: DEGAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE THE
BARREL, LOADER, AIR SYSTEM AND ANY PAINTBALLS
TO MAKE THE MARKER EASIER AND SAFER TO WORK
ON.
WARNING
FIG 16.2 FIG 16.3
FIG 16.4
FIG 16.5
FIG 16.6
FIG 16.1
WARNING: IF YOU ARE AT ALL UNSURE OF PERFORMING
THE MAINTENANCE PROCEDURE PLEASE CONTACT
YOUR NEAREST ECLIPSE SERVICE CENTRE. SEE PAGES
7273
WARNING
CONTENTS
ORIENTATION
QUICK SET-UP
USING YOUR EGO10
ADVANCED SET-UP
MENU TREE
MAINTENANCE
FAULT FINDING
SERVICE CENTERS
PARTS LIST
SPARES & ACCESSORIES
INDEX
61.
MAINTENANCE
MAINTENANCE
QUICK GUIDE