Manual
CONTINUED
Clean and check the condition of the single internal
006 NBR90 o-ring in the front of the OOPS insert, replace
if necessary SEE FIGURE 18.5. Lubricate all three of these
o-rings liberally using Eclipse Grease SEE FIGURE 18.6.
Replace the OOPS insert into the OOPS body ensuring
that the o-ring end goes in rst, pushing it into place SEE
FIGURE 18.7
.
Lubricate the narrow end of the OOPS pin with a smear
of Eclipse Grease and push the pin, narrow end rst, into
the OOPS body so that it sits in the OOPS insert and pokes
through the front of the OOPS body SEE FIGURE 18.8.
Screw the OOPS knob back onto the OOPS body until only
a couple of threads are showing SEE FIGURE 18.9.
Reconnect the macroline hose to the tting on the OOPS
body SEE FIGURE 18.10.
You have now successfully cleaned and maintained your
On/O purge system.
FIG 18.10FIG 18.9
FIG 18.8FIG 18.7
FIG 18.6
FIG 18.5
WARNING: IF YOU ARE AT ALL UNSURE OF PERFORMING
THE MAINTENANCE PROCEDURE PLEASE CONTACT
YOUR NEAREST ECLIPSE SERVICE CENTRE. SEE PAGES
7273
WARNING
CONTENTS
ORIENTATION
QUICK SET-UP
USING YOUR EGO10
ADVANCED SET-UP
MENU TREE
MAINTENANCE
FAULT FINDING
SERVICE CENTERS
PARTS LIST
SPARES & ACCESSORIES
INDEX
67.
MAINTENANCE
MAINTENANCE
QUICK GUIDE