THE EGO10 TRIGGER
ASSEMBLY
Having removed the trigger frame completely from the
Ego10 body (see page 57) hold the bearing carrier in place
in the top of the frame SEE FIGURE 15.1. Gently lift the
bearing carrier and trigger assembly free from the frame
taking care not to damage the micro-switch or the Opto
sensors SEE FIGURE 15.2.
Using a 1/16” hex key, loosen the trigger pin retaining set
screw from the bottom of the trigger SEE FIGURE 15.3.
Use a small hex key to push the trigger pin out of the
bearing carrier from one side SEE FIGURE 15.4.
Clean the trigger and bearing carrier thoroughly and also
clean the space within the frame that the trigger sits into.
Carefully remove the trigger spring from the spring hole
in the top of the trigger and clean o any paint debris or
moisture from it SEE FIGURE 15.5.
WARNING: DEGAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE THE
BARREL, LOADER, AIR SYSTEM AND ANY PAINTBALLS
TO MAKE THE MARKER EASIER AND SAFER TO WORK
ON.