MAINTAINING THE
RAMMER
Pull the bolt pin upwards so that it disengages the rammer,
allowing the bolt to be removed via the rear of the Ego10
SEE FIGURE 12.1.
Using a 3/16" hex key, unscrew and remove the rammer
cap at the rear of the Ego10 SEE FIGURE 12.2.
Raise the front of the Ego10 and tap the Ego10 onto your
hand until the rammer falls into the palm of your hand
SEE FIGURE 12.3.
Thoroughly clean the rammer shaft and all of its seals,
paying special attention to the 009 NBR 70 o-ring on the
middle of the shaft SEE FIGURE 12.4), the rear 011 NBR 70
o-ring SEE FIGURE 12.5 and the condition of the rammer
bumper cushion in the rammer cap SEE FIGURE 12.6
OVERLEAF.
Replace any worn seals/bumpers using authentic Eclipse
Ego10 spare parts.
WARNING: DEGAS YOUR MARKER, DISCHARGING ANY
STORED GAS IN A SAFE DIRECTION, AND REMOVE THE
BARREL, LOADER, AIR SYSTEM AND ANY PAINTBALLS
TO MAKE THE MARKER EASIER AND SAFER TO WORK
ON.
WARNING
FIG 12.3
FIG 12.5
FIG 12.4
FIG 12.1
FIG 12.2
54.