Manual

(CONTINUED)
Clean and check the condition of the single internal
o-ring in the front of the OOPS Insert, replace if
necessary (SEE FIGURE 18.5). Lubricate all three of these
o-rings liberally using Eclipse Grease (SEE FIGURE 18.6).
Replace the OOPS Insert into the OOPS Body ensuring
that the o-ring end goes in first, pushing it into place
(SEE FIGURE 18.7).
Lubricate the narrow end of the OOPS Pin with a Smear
of Eclipse Grease and push the pin, narrow end first,
into the OOPS Body so that it sits in the OOPS Insert
and pokes through the front of the OOPS Body (SEE
FIGURE 18.8).
Screw the OOPS Knob back onto the OOPS body until
only a couple of threads are showing (SEE FIGURE 18.9).
Reconnect the macroline hose to the fitting on the
OOPS Body (SEE FIGURE 18.10).
You have now successfully cleaned and maintained
your On/Off Purge System.
FIG 18.10FIG 18.9
THE EGO9 ON/OFF PURGE
SYSTEM (OOPS)
Having disconnected the macroline hose from the
fitting on the OOPS Body, unscrew the OOPS Knob
from the OOPS Body (SEE FIGURE 18.1). Clean off any
dirt, debris or moisture from the OOPS Knob and the
threaded section of the OOPS Body.
Use an appropriately sized hex key to push the OOPS
Pin out of the OOPS Body (SEE FIGURE 18.2) and then
remove the OOPS Insert using a pair of needle nosed
pliers (SEE FIGURE 18.3).
Clean and check the condition of the two o-rings on
the outside of the OOPS Insert, replacing as necessary
(SEE FIGURE 18.4).
FIG 18.2
FIG 18.3
FIG 18.1
FIG 18.4
WARNING: DE-GAS YOUR MARKER, DISCHARGING
ANY STORED GAS IN A SAFE DIRECTION, AND REMOVE
THE BARREL, LOADER AND AIR SYSTEM TO MAKE THE
MARKER EASIER TO WORK ON.
WARNING
FIG 18.8FIG 18.7
FIG 18.6
FIG 18.5