Manual

FULL
THE BREECH FULL TIME PARAMETER
Tumbling paintballs can take time to settle in the
breech before they can be successfully fired. This
parameter is used to set the amount of time that a
paintball has to be in the breech before the Ego9 is
allowed to fire. This parameter can be set between 1.0
and 20 milliseconds in 0.5ms increments.
PULL TM
THE TRIGGER PULL TIME PARAMETER
The PULL TM parameter is used to set the minimum
amount of time that the trigger must be pulled before
it is recognised as a valid trigger pull. This parameter
can be set between 3.0 and 20.0 milliseconds in 0.5
increments.
REL TM
THE TRIGGER RELEASE TIME PARAMETER
The REL TM parameter is used to set the minimum
amount of time that the trigger must be released
before it is recognised as a valid trigger release.
This parameter can be set between 3.0 and 25.0
milliseconds in 0.1 millisecond increments.
PULL PT
THE TRIGGER PULL POINT PARAMETER
The PULL PT parameter is only available if OPTO has
been selected in the Hardware Menu. PULL PT defines
the point at which the trigger is considered pulled and
is adjustable between 51% and 99% in 1% increments.